Tools

Domain Tool What it does
Microbiology / QC cfu CFU enumeration from dilution plates (USP ⟨61⟩/⟨62⟩, EP 2.6.12)
mpn Most probable number
media-fill Aseptic process simulation (USP ⟨1116⟩)
growth-curve Logistic / Gompertz growth kinetics
bioburden-spc I-MR control charts (Western Electric)
Sterility / thermal d-z-f0 D-value, Z-value, F0 lethality
sterility Sterility-test sample sizes (USP ⟨71⟩)
endotoxin Endotoxin limits + MVD (USP ⟨85⟩)
Molecular biology qpcr ΔΔCt relative gene expression
primers Annealing temperature + dimer analysis
restriction Restriction digest simulation
phylogeny Neighbor-joining trees
Analytical elisa 4PL standard curves
lod-loq LOD / LOQ (ICH Q2(R1))
hplc-sst HPLC system suitability
Lab operations hemocytometer Cell count / viability
pipette-cal Pipette calibration (ISO 8655)

cfu — worked example

A 1:10 serial dilution plated at 0.1 mL per plate with duplicate counts:

Dilution factor Replicate A Replicate B
0.01 (10⁻²) 245 231
0.001 (10⁻³) 42 38

All four counts are inside the USP/EP countable range of 30–300 CFU. For each plate:

CFU/mL = colony count / (volume plated in mL × dilution factor)
245 / (0.1 × 0.01)  = 245,000 CFU/mL
231 / (0.1 × 0.01)  = 231,000 CFU/mL
 42 / (0.1 × 0.001) = 420,000 CFU/mL
 38 / (0.1 × 0.001) = 380,000 CFU/mL

The reported mean across the four usable plates is:

(245,000 + 231,000 + 420,000 + 380,000) / 4 = 319,000 CFU/mL

The between-plate CV is about 29.82% (sample standard deviation ≈ 95,118 CFU/mL).

Run the same calculation with the one-line command:

lab-tools cfu quick --counts 245,231,42,38 --dilutions 0.01,0.001 --replicates 2 --volume 0.1

The report prints CFU/mL: 3.19e+05 and the same uncertainty and dilution details.

Development

pip install -e . pytest
python -m pytest -q

The project grows through a daily backlog-driven automation (see BACKLOG.md and scripts/): one item is implemented and committed per day, only if the test suite stays green.

License

MIT © Collins Amatu Gorgerat

About

CLI tools for pharmaceutical, microbiology and molecular-biology laboratory data

Resources

Stars

0 stars

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages