Size the solar panel and battery for an always-on or duty-cycled embedded node (ESP32, ATmega, nRF, LoRa...) and simulate a whole year hour by hour to see whether it survives the worst weeks.
Live demo: https://projectbin07-stack.github.io/solar-node-sizer/
Results are model estimates. The built-in weather is synthetic and illustrative (fitted to a single year of data per place), the example currents are datasheet-order figures, and nothing here has been validated against a physical node's measured battery data. Use it to compare designs and find the order of magnitude, then measure your node and leave margin.
The same ESP32 node with a low-Iq LDO, 0.075 Wp and 500 mAh in a Berlin-like climate (dark theme, link): the heatmap shows the battery draining from November to February, the outages in red, and the worst week in late December.
"Will a 1 W panel and an 18650 keep my ESP32 alive through the monsoon?" is usually answered with a back-of-the-envelope "sun-hours x panel watts" line and a guess for the battery. The things that actually decide it are easy to miss on paper: the regulator's quiescent current and dropout, a linear charger throwing away a third of the panel, the cut-off voltage that leaves part of the battery unusable, self-discharge, and above all runs of dark days. This tool puts all of them in one hourly simulation, for a synthetic year or for real PVGIS data for your site, and searches panel and battery sizes for the cheapest combination that never browns out.
- Load profile: any number of states (deep sleep, sensor read, radio TX...) with current, period, duration and optional time-of-day window; daily energy budget per state in mAh and mWh.
- Regulators: none, LDO (quiescent current and dropout, so a battery voltage floor) and switching converters with a per-state efficiency curve. Presets for an MCP1700-class LDO, an AMS1117-class dev-board LDO, a buck and a buck-boost.
- Solar resource: NOAA solar position, Haurwitz clear sky, Erbs beam/diffuse split, isotropic transposition to the panel tilt and azimuth; seeded day-to-day cloudiness with presets for Bengaluru, Mumbai, New Delhi, Chennai, Guwahati, Nairobi and Berlin; or your own PVGIS hourly or TMY CSV.
- Panel and charger: Wp, tilt, azimuth, temperature coefficient (NOCT model), soiling and other losses; MPPT or linear/PWM charger with efficiency and current limit.
- Battery: Li-ion, LiFePO4, NiMH and low self-discharge NiMH presets; cells in series, capacity, usable depth, cut-off voltage, self-discharge, charge efficiency, C-rate with a taper near full, no charging below 0 degC or above 45 degC, cold derating, peak-current check.
- Hourly year simulation with warm-up, brown-out and restart: energy harvested, stored, clipped and delivered, hours of downtime, lowest charge, days of autonomy (how long a full battery lasts with no sun, load plus self-discharge) and the worst consecutive-days deficit.
- Sizer: simulates a grid of panel and battery sizes (chosen from the load), plots the Pareto frontier and picks the lowest-cost combination that meets a downtime target.
- App: load-profile table, stacked bar of daily energy per state, year heatmap of state of charge (day x hour), monthly harvest vs load bars, worst-week zoom, sizing chart, one-line verdict, warnings about the parts combination, shareable URLs, configuration JSON import (file picker or drag and drop, including the export of embedded-power-profiler), CSV export, light/dark, phone layout. No external assets, no network calls, no build step.
- CLI:
simulateandsizeon JSON configurations, text or JSON output, CSV export, deterministic for a seed.
In the browser: open the live demo. It starts with an ESP32 + BME280 node reporting over Wi-Fi every 10 minutes in a Bengaluru-like climate. Try:
- Pick the ESP32 dev board with AMS1117 LDO example: the regulator's 5 mA ground current makes the regulator the biggest load, and its 1.1 V dropout leaves only 7 % of the Li-ion cell usable.
- Set the panel to 0.02 Wp and look at the heatmap and the worst week.
- Change the weather seed to see another possible year from the same climate statistics, or load a PVGIS file (below).
Locally (Node 22 or newer):
git clone https://github.com/projectbin07-stack/solar-node-sizer.git
cd solar-node-sizer
npm ci # dev tools only
npm run serve # then open http://127.0.0.1:8000/Any static file server works; ES modules do not load from file://.
URL parameters hold every setting that differs from the default (for
example ?wp=0.5&mah=1000&cl=mumbai&lat=19.08&lon=72.88), the load as
L=name~mA~every~duration[~from~to];... with b for the base state, and
theme=light|dark. Copy link copies the current setup. A loaded PVGIS
file is not part of the link.
Importing a configuration. "Or import a configuration JSON" under
Start from (or dropping a .json file anywhere on the page) reads the
same JSON the CLI reads. Every section in the file replaces the current
one; sections it leaves out keep their current values, so a measured load
profile exported by embedded-power-profiler (epp export LOG --solar-node-sizer load.json, which holds only name, note and load) replaces the load
table and keeps your location, panel, battery and regulator. A full
configuration (--full-config) replaces everything. A file that is not
valid JSON or not a valid configuration is reported and nothing changes.
Dropping a .csv file loads it as PVGIS data.
PVGIS is a free tool of the European Commission's Joint Research Centre and covers India, the rest of Asia, Africa, Europe and the Americas.
- Open https://re.jrc.ec.europa.eu/pvg_tools/en/ and click your site on the map (or type the coordinates).
- Choose the Hourly data tab. Pick a radiation database and a single year (start = end year; try a few different years, a bad monsoon year matters more than an average one).
- Under "Mounting type" choose Fixed, enter your panel's slope (tilt) and azimuth (PVGIS: 0 = south, 90 = west, -90 = east). PV power and components are optional; this tool only uses the irradiance and the air temperature.
- Download CSV. Load it with "Or use a PVGIS hourly CSV you
downloaded" in the app, or pass
--pvgis file.csvto the CLI. The tilt and azimuth then come from the file.
The TMY tab works too (typical meteorological year; the tool transposes it to the panel tilt you set). The file is read locally and never uploaded. PVGIS times are UTC; they are shifted to local time using the UTC offset you set (rounded to the hour).
$ node bin/solar-node-sizer.js --help
solar-node-sizer 0.1.2: solar panel and battery sizing for embedded nodes
Usage:
solar-node-sizer simulate <config.json> [options]
solar-node-sizer size <config.json> [options]
solar-node-sizer presets [--json]
solar-node-sizer --help | --version
simulate runs the hour-by-hour year for the panel and battery in the
configuration and prints the energy budget, the energy flows and whether
the node stays up. size simulates every combination of the sizer's panel
and battery grids and prints the downtime table, the Pareto frontier and
the lowest-cost combination that meets the downtime target.
Options:
--pvgis <file.csv> use a PVGIS hourly-data or TMY CSV you downloaded
instead of the synthetic weather
--seed <n> synthetic weather seed (overrides location.seed)
--wp <W> panel size (overrides panel.wp)
--mah <mAh> battery capacity (overrides battery.capacityMah)
--json print JSON instead of text
--csv <file> (simulate) write the hourly results to a CSV file
Results are model estimates. The synthetic weather is illustrative; see
docs/models.md for the equations and their limits.
Example configurations are in examples/ (all illustrative).
The AMS1117 dev-board example, simulated:
$ node bin/solar-node-sizer.js simulate examples/esp32-devboard-ams1117.json
config ESP32 dev board (AMS1117 LDO), Wi-Fi report every 10 min, Mumbai (illustrative)
weather Synthetic year: Mumbai-like (heavy SW monsoon Jun-Sep), seed 1
panel 1 Wp, tilt 20 deg, azimuth 180 deg, linear charger, limit 500 mA
battery Li-ion (NMC/LCO, e.g. 18650), 1S 2500 mAh = 9.25 Wh, usable 0.617 Wh (floor 93.3 %, set by regulator)
regulator LDO 3.3 V, AMS1117-class (5 mA ground current, 1.1 V dropout)
daily budget (at the battery, nominal voltage)
Deep sleep (RTC timer) 23.9 h 0.358 mAh 1.18 mWh
Boot + BME280 read 0.012 h 0.48 mAh 1.58 mWh
Wi-Fi connect + MQTT 0.12 h 14.4 mAh 47.5 mWh
regulator overhead 450 mWh
total 500 mWh/day = 135 mAh/day, average 5.63 mA
year (365 days)
panel output 1475 Wh
charger output 996 Wh
stored in battery 209 Wh (charge loss 11 Wh)
clipped 776 Wh (battery full or charge limits)
delivered to node 205 Wh (unserved 0.376 Wh)
self-discharge 3.34 Wh
stored energy 9.11 -> 9.11 Wh
downtime 16.3 h in 1 outage(s), longest 16.3 h
lowest charge 93.3 % on 16 Aug
worst deficit 0.465 Wh over 3 day(s) from 14 Aug
autonomy 1.21 days from full
month stored Wh load Wh down h
Jan 17.8 17.5 0
Feb 16 15.8 0
Mar 17.8 17.5 0
Apr 17.2 16.9 0
May 17.8 17.5 0
Jun 17.2 16.9 0
Jul 17.8 17.5 0
Aug 17.3 17.1 16.3
Sep 17.2 16.9 0
Oct 17.7 17.5 0
Nov 17.2 16.9 0
Dec 17.7 17.5 0
note: The regulator needs at least 4.10 V, so only 7 % of the battery is usable (below that the output sags).
note: The regulator draws 5.0 mA all the time, which usually dominates a sleeping node's budget.
note: Synthetic weather: seeded random cloudiness around monthly statistics PVGIS-ERA5 at 19.08 N 72.88 E, fitted to PVGIS 2020 hourly data (one year, horizontal plane); illustrative; not a forecast or a climatology.
result: Down 16.3 hours over the year, all in Aug; 1 brown-out(s), longest 16.3 h. Battery gives 1.21 days of autonomy.
Sizing the ESP32 example (grid chosen from the load; ok = no downtime,
peak = too small for the 120 mA Wi-Fi burst at 2 C):
$ node bin/solar-node-sizer.js size examples/esp32-wifi-10min.json
config ESP32 + BME280, Wi-Fi report every 10 min, Bengaluru (illustrative)
weather Synthetic year: Bengaluru-like (SW monsoon Jun-Sep, NE monsoon Oct-Dec), seed 1
target downtime <= 0 h per year (70 simulations)
downtime hours (rows: panel Wp, columns: battery mAh)
Wp \ mAh 75 100 150 200 300 500 750
0.01 5128 5131 5137 5144 5156 5182 5216
0.015 3309 3311 3317 3322 3335 3360 3394
0.02 1501 1498 1502 1507 1519 1544 1577
0.03 19.9 ok ok ok ok ok ok
0.05 ok ok ok ok ok ok ok
0.075 ok ok ok ok ok ok ok
0.1 ok ok ok ok ok ok ok
0.15 ok ok ok ok ok ok ok
0.2 ok ok ok ok ok ok ok
0.3 ok ok ok ok ok ok ok
ok = no downtime; peak = below 60 mAh the battery cannot deliver the peak current
frontier (smallest battery for each panel size that meets the target)
0.03 Wp + 100 mAh lowest charge 28.6 %
0.05 Wp + 75 mAh lowest charge 79.7 %
best 0.05 Wp + 75 mAh (relative cost 0.125 with 1/Wp and 1/Ah)
With a PVGIS file downloaded as described above (Bengaluru, PVGIS-ERA5, 2020, slope 15 deg, azimuth 0) and a 0.05 Wp panel with a 100 mAh cell:
$ node bin/solar-node-sizer.js simulate examples/esp32-wifi-10min.json --wp 0.05 --mah 100 --pvgis Timeseries_12.972_77.594_E5_15deg_0deg_2020_2020.csv
config ESP32 + BME280, Wi-Fi report every 10 min, Bengaluru (illustrative)
weather PVGIS hourly data at 12.972, 77.594 (PVGIS-ERA5, 2020-2020)
panel 0.05 Wp, tilt 15 deg, azimuth 180 deg, linear charger, limit 500 mA
battery Li-ion (NMC/LCO, e.g. 18650), 1S 100 mAh = 0.37 Wh, usable 0.296 Wh (floor 20 %, set by dod)
regulator LDO 3.3 V, low Iq (MCP1700-class: 1.6 uA, 0.18 V dropout)
daily budget (at the battery, nominal voltage)
Deep sleep (RTC timer) 23.9 h 0.358 mAh 1.18 mWh
Boot + BME280 read 0.012 h 0.48 mAh 1.58 mWh
Wi-Fi connect + MQTT 0.12 h 14.4 mAh 47.5 mWh
regulator overhead 6.24 mWh
total 56.5 mWh/day = 15.3 mAh/day, average 0.637 mA
year (366 days)
panel output 75.6 Wh
charger output 50.7 Wh
stored in battery 23.2 Wh (charge loss 1.22 Wh)
clipped 26.3 Wh (battery full or charge limits)
delivered to node 23.1 Wh (unserved 0 Wh)
self-discharge 0.13 Wh
stored energy 0.344 -> 0.344 Wh
downtime 0 h in 0 outage(s), longest 0 h
lowest charge 74.4 % on 5 Dec
worst deficit 0.0478 Wh over 2 day(s) from 3 Dec
autonomy 5.22 days from full
month stored Wh load Wh down h
Jan 1.98 1.96 0
Feb 1.84 1.83 0
Mar 1.97 1.96 0
Apr 1.91 1.9 0
May 1.97 1.96 0
Jun 1.91 1.9 0
Jul 1.97 1.96 0
Aug 1.97 1.95 0
Sep 1.9 1.89 0
Oct 1.97 1.96 0
Nov 1.9 1.89 0
Dec 1.95 1.95 0
note: The charger can push 500 mA but the model lets this battery accept only 50 mA (0.5 C).
note: Time zone 5.5 h rounded to 6 h to align the hourly rows with local hours.
result: Survives the year with 5.22 days of autonomy from a full battery; lowest state of charge 74.4 % around 5 Dec.
--json prints the same results as JSON (budget, totals, monthly figures,
downtime, warnings); size --json adds the full downtime grid.
A configuration is JSON; every field is optional and defaults to the ESP32
example. See examples/esp32-wifi-10min.json
for the full set; node bin/solar-node-sizer.js presets lists the climates,
cities, chemistries and regulators.
Full equations, sources and limits: docs/models.md. In short:
| Part | Model | Main limits |
|---|---|---|
| Sun position | NOAA calculator equations (Meeus), checked against Meeus examples and the NREL SPA example to < 0.01 deg | none that matter at hourly resolution |
| Clear sky | Haurwitz: GHI = 1098 cos z exp(-0.059 / cos z) |
no turbidity or altitude; the cloud factors are fitted relative to it |
| Diffuse split | Erbs: diffuse fraction from kt = GHI / (I0 cos z) |
a correlation, scattered for individual hours |
| Tilted panel | isotropic sky + ground albedo + ASHRAE IAM (b0 = 0.05) | no circumsolar/horizon brightening, no shading |
| Synthetic weather | daily index k = clamp(mean_m + std_m z_d, 0.03, 1.1), AR(1) z_d, fitted to PVGIS 2020 |
one year per place, one factor per day, illustrative |
| Panel | P = Wp G/1000 (1 + gamma (Tc - 25)) (1 - soiling)(1 - losses), Tc = Ta + G (NOCT - 20)/800 |
no low-light, spectral or mismatch model beyond the loss factor |
| Charger | MPPT: P eta; linear/PWM: (P / Vmp) eta Vbat; both capped at the current limit |
panel voltage assumed high enough |
| Load | duty-cycle average per hour; LDO Vb (I + Iq), switching I Vout / eta(I) + Vb Iq |
hourly averages, no inrush or sag |
| Battery | energy bucket, usable window from DoD / cut-off / regulator minimum, charge efficiency, C-rate taper solved within the hour, 0-45 degC charging, cold derating, self-discharge | coarse OCV tables, no internal resistance, no ageing |
On the one site where it can be compared, the synthetic Bengaluru year gives 1943 kWh/m^2 on a 15 deg south-facing plane (seed 1; 1873-1958 for seeds 1-3) against 1954 kWh/m^2 from PVGIS-ERA5 for 2020, the year the preset was fitted to. That checks the fitting and the geometry, not the battery model.
index.html, styles.css static page, no build step
src/core/ (DOM-free, tested under Node)
solar.js sun position, clear sky, Erbs split, transposition
weather.js climate presets, seeded daily cloudiness, air temperature
pvgis.js PVGIS hourly-data and TMY CSV parser
resource.js hourly plane-of-array irradiance + temperature in local time
load.js load states, schedules, regulators, daily budget
pv.js panel output and charger models
battery.js chemistries, OCV tables, derating, self-discharge
config.js configuration defaults, validation, battery limits, warnings
simulate.js hourly simulation, charge integration, deficit
sizer.js grid search, automatic grids, Pareto frontier
model.js glue: resource -> simulation -> summary, JSON, CSV
examples.js the example configurations (same as examples/*.json)
src/ui/
state.js URL <-> configuration, JSON import (tested)
draw.js canvas charts with hover tooltips
app.js form wiring
src/cli.js, bin/solar-node-sizer.js command-line interface
scripts/fit-climate.js fits a climate preset to a PVGIS file you downloaded
scripts/browser-import-test.js headless-browser test of the JSON import (CI)
The browser and the CLI run exactly the same src/core code.
npm run check # Prettier, tsc --checkJs --strict, node:test with coverage thresholdsOn the development machine (Windows 11, Node 25) npm run coverage reports
93 tests, 93 passing, with 99.8 % line, 95.1 % branch and 98.2 % function
coverage over the measured files (the canvas and DOM code in
src/ui/app.js and src/ui/draw.js is excluded; it is exercised by the
browser smoke test in CI).
What the tests check against:
- Solar position: Meeus examples 25.a and 28.b (declination, apparent longitude, equation of time) and the NREL SPA worked example (zenith and azimuth within 0.05 deg).
- Clear sky: zero at night, 1035 W/m^2 overhead, peak in the solar-noon hour, plausible annual and noon magnitudes.
- Energy balance:
stored - delivered - self-discharge = change in stored energyto 1e-9 Wh, monthly sums equal the totals, clipping and charge-efficiency identities. - Bounds and behaviour: state of charge within [0, 1] and above the floor whenever the node runs; a node without a panel runs for about its autonomy; no charging below 0 degC.
- Autonomy: hand-stepped values with and without self-discharge, a
brute-force hourly loop, the continuous solution, the old
usable / daily loadresult when self-discharge is zero, and an exact match with a no-sun simulation run when the load does not depend on the battery voltage. - Regulators: hand-computed LDO and buck battery power; the buck beats the LDO on the radio burst and loses on a pure sleep load.
- PVGIS parsing on hand-written files in the documented layout
(
tests/fixtures/, numbers typed for the tests, not PVGIS output): metadata, azimuth conversion, components, TMY re-timing, CRLF and BOM, bad values, gaps. - Sizer: more panel never increases downtime (three climates); more battery never increases downtime with self-discharge and restart margin set to zero (with them it can, see docs/models.md); frontier non-dominated; lowest cost.
- Determinism: same seed, same year and same CLI output.
- Load windows: a once-a-day event in a one-hour
from/towindow is one event a day (1.6667 mAh at 100 mA for 60 s), the same as without the window. - Configuration import: a real embedded-power-profiler export (load only, and full configuration) gives the same configuration as the CLI; bad files are rejected with a message.
- CLI output shape, URL round trips, configuration errors.
CI runs the checks on Ubuntu and Windows with Node 22 and 24, smoke-tests
the CLI, and loads the page in headless Chrome to check that the simulation
and the sizer ran. A second headless-Chrome step
(scripts/browser-import-test.js, DevTools protocol, no dependencies)
imports an embedded-power-profiler export through the file input and by a
synthetic drop event and checks the page's results against the CLI's
(512 mWh/day, 14.3 days autonomy).
- Not validated against hardware. No measured battery voltage, current or state of charge from a real node has been compared with the simulation.
- Synthetic weather is illustrative: one fitted year per place, one cloud factor per day (no intra-day variability), no inter-annual variation beyond the random seed. Use PVGIS data, ideally several years, for real decisions.
- Hourly resolution: duty cycles are averaged within the hour; peak currents are only checked against a C-rate limit; no voltage sag, internal resistance, brown-out detector timing or inrush.
- Battery model: coarse OCV tables, temperature-independent self-discharge, no ageing or capacity fade, battery temperature = air temperature.
- Panel model: isotropic sky, no shading, a single loss factor for low-light behaviour and real-vs-label output of cheap panels.
- Half-hour time zones are rounded to the hour when aligning PVGIS data.
- Several PVGIS years at once, reporting the worst year.
- Battery internal resistance and voltage sag for high-current bursts.
- Enclosure temperature model.
- Import of measured node logs (voltage over time) to compare with the simulation.
MIT, see LICENSE. PVGIS data is (c) European Union; none is included in this repository.