Modbuska

Build License: MIT .NET

Pronounced "mod-BAS-ka" (Модбаска).

A small, dependency-light Modbus RTU master library for .NET. Built for quick device testing and prototyping: open a serial port, read or write registers, check the result.

  • Synchronous API with result objects instead of exceptions for protocol and I/O errors
  • Modbus RTU over System.IO.Ports (RS-232 / USB-UART / USB-RS485 adapters)
  • Strict response validation: CRC, slave address, function code, byte count, write echo
  • Verified on real hardware (ESP8266 slave, test firmware included)

Scope: master/client side only, RTU only (no Modbus TCP, no slave/server). Modbus RTU has no authentication or encryption. Do not rely on it for security.

Features

  • DI registration via AddModbus()
  • Optional structured logging with hex TX/RX frame traces (see Logging)
  • Supported function codes:
    • FC1 - Read Coils
    • FC2 - Read Discrete Inputs
    • FC3 - Read Holding Registers
    • FC4 - Read Input Registers
    • FC5 - Write Single Coil
    • FC6 - Write Single Register
    • FC15 - Write Multiple Coils
    • FC16 - Write Multiple Registers
  • Example console application and ESP8266 test firmware included in the repository

Requirements

  • .NET 10
  • A serial port (physical, USB adapter, or virtual)

Installation

Clone the repository and reference the project:

git clone https://github.com/Ledrunning/Modbuska.git
dotnet add <your-project> reference Modbuska/src/Modbuska.ModbusManager/Modbuska.ModbusManager.csproj

Quick start

ModbusMessage is abstract, so declare a tiny request type once in your project:

using Modbuska.ModbusManager.Model;

public sealed class RequestMessage : ModbusMessage { }

Then register the services, open the port and send a request:

using Microsoft.Extensions.DependencyInjection;
using Modbuska.ModbusManager.Extension;
using Modbuska.ModbusManager.Model;
using Modbuska.ModbusManager.Service;

var services = new ServiceCollection();
services.AddModbus();

using var provider = services.BuildServiceProvider();
var serial = provider.GetRequiredService<SerialConnectionService>();
var modbus = provider.GetRequiredService<ModbusRtuService>();

var open = serial.Open(new SerialPortSettings
{
    PortName = "COM3",          // "/dev/ttyUSB0" on Linux
    BaudRate = 115200,
    DataBits = 8,
    Parity = System.IO.Ports.Parity.None,
    StopBits = System.IO.Ports.StopBits.One,
    ReadTimeout = 500,          // ms, default 500
    WriteTimeout = 100          // ms, default 100
});

if (!open.Success)
{
    Console.WriteLine(open.ErrorMessage);
    return;
}

// Read 4 holding registers starting at address 0 from slave 1
var request = new RequestMessage { Address = 1, Start = 0, Register = 4 };
var (result, registers) = modbus.SendFc3(request);

if (result.Success)
    Console.WriteLine(string.Join(", ", registers));
else
    Console.WriteLine($"Error: {result.ErrorMessage}");

Always check result.Success before using the returned data. On failure the data is a default value.

In RequestMessage, Start is the first address and Register is the number of registers or coils.

Writing

// FC6: write a single holding register (slave 1, address 0, value 555)
var (writeResult, echoed) = modbus.SendFc6(
    new RequestMessage { Address = 1, Start = 0, Register = 1 }, 555);

// FC16: write multiple holding registers
var fc16 = modbus.SendFc16(
    new RequestMessage { Address = 1, Start = 0, Register = 3 },
    [10, 20, 30]);

// FC5: write a single coil
var (coilResult, coilState) = modbus.SendFc5(
    new RequestMessage { Address = 1, Start = 0, Register = 1 }, true);

Behavior and validation

  • Request limits follow the Modbus specification and are checked before anything is sent:
    • reads: up to 2000 coils/inputs (FC1/FC2), up to 125 registers (FC3/FC4)
    • writes: up to 1968 coils (FC15), up to 123 registers (FC16)
    • count must be greater than 0
  • Slave address must be 1-247. Address 0 is broadcast:
    • writes are sent without waiting for a response and return success with default data (there is no confirmation)
    • reads with address 0 are rejected
  • Responses are validated for CRC, slave address, function code, byte count and (for writes) the echoed address and value or count. Modbus exception responses are returned as failed results.
  • Thread safety: each request/response transaction is serialized with a lock, so concurrent calls on the same port will not mix frames. Calls are blocking.
  • Timeouts are reported as failed results, not thrown.
  • Registers are ushort (unsigned 16-bit), as defined by the Modbus specification.

Hardware test with ESP8266 (NodeMCU V3 board)

The repository includes a demo ESP8266 slave firmware in src/FirmwareSlave/ModbuskaSlaveTester, built with PlatformIO on top of the modbus-esp8266 library (check its license for your use). Together with the Modbuska.Example console app, it lets you verify everything on real hardware.

What the firmware does: slave ID 1, 16 coils / discrete inputs / input registers / holding registers. Coils start as false, discrete inputs alternate true/false, input registers are i * 100, holding registers are i * 10. The built-in LED turns on when coil 0 is 1 or holding register 0 is 555.

Preparation

  1. Build and flash the firmware with PlatformIO (pio run -t upload from the firmware project folder).
  2. Connect the board to your computer over USB.
  3. Run Modbuska.Example and choose Open serial with:
    • Port name: your port (e.g. COM3 or /dev/ttyUSB0)
    • Baud rate: 115200, Data bits: 8, Parity: None, Stop bits: One

Modbuska.Example console menu

Test scenarios

Run the read checks (FC1-FC4) first on a freshly reset board, because the write checks change its state. For every function use slave address 1.

Function Console input Expected result
FC1 Read Coils start 0, count 8 Coils: False, False, False, False, False, False, False, False
FC2 Read Discrete Inputs start 0, count 8 Inputs: True, False, True, False, True, False, True, False
FC3 Read Holding Registers start 0, count 4 Holding registers: 0, 10, 20, 30
FC4 Read Input Registers start 0, count 4 Input registers: 0, 100, 200, 300
FC5 Write Single Coil address 0, value 1 Returned coil state: True and the LED turns on. Write 0 and the LED turns off.
FC6 Write Single Register address 0, value 555 Returned register value: 555 and the LED turns on. Write any other value (e.g. 10) and the LED turns off.
FC15 Write Multiple Coils start 0, count 4, values 1,0,1,1 Written coils: True, False, True, True. Verify with FC1 (start 0, count 4).
FC16 Write Multiple Registers start 0, count 3, values 100,200,300 Written registers: 100, 200, 300. Verify with FC3 (start 0, count 3).

Note: the LED on ESP8266 boards is active-low. The firmware handles this, so "on" in the table means the LED is physically lit.

Example project

Modbuska.Example is a console app with a menu-based execution of all implemented Modbus functions through DI. It enables the console logger at Trace level, so you can watch every frame on the wire while you test.

Logging

The library depends only on Microsoft.Extensions.Logging.Abstractions and does not configure any logging provider itself: AddModbus() intentionally does not call AddLogging(). The host application chooses and configures the providers (console, Serilog, etc.).

Both ModbusRtuService and SerialConnectionService accept an optional ILogger<T> in their constructors. When no logger is provided, NullLogger<T>.Instance is used, so logging is completely optional and never throws.

When a logger is wired up:

  • Trace: every TX/RX frame as hex
  • Debug: completed operations (slave, function, item count); validation failures (invalid address, count == 0, limit exceeded)
  • Warning: transaction failures (serial port closed, rejected broadcast read, timeout, invalid CRC, Modbus exception response with its code, write echo mismatch, response validation errors). The exception is passed along, so its type and stack trace are preserved.
  • Error: serial port open/close failures
  • Information: serial port opened/closed (with port settings)

All log messages use named template parameters in PascalCase (SlaveId, Function, Frame, PortName, ...), so the values are available as structured fields for Serilog / Elasticsearch / Kibana.

Enabling frame traces (console provider)

using Microsoft.Extensions.DependencyInjection;
using Microsoft.Extensions.Logging;
using Modbuska.ModbusManager.Extension;

var services = new ServiceCollection();
services.AddLogging(builder => builder
    .AddConsole()
    .SetMinimumLevel(LogLevel.Trace));
services.AddModbus();

With Trace enabled you will see output like:

TX SlaveId=1 Function=ReadHoldingRegisters Frame=01 03 00 00 00 02 C4 0B
RX SlaveId=1 Function=ReadHoldingRegisters Frame=01 03 04 00 0A 00 0B 9B F6

In a real application you usually want Trace for Modbuska only and a quieter level for everything else:

services.AddLogging(builder => builder
    .AddConsole()
    .SetMinimumLevel(LogLevel.Warning)
    .AddFilter("Modbuska", LogLevel.Trace));

Serilog example

Packages: Serilog.Extensions.Logging and Serilog.Sinks.Console (add a file or Elasticsearch sink the same way).

using Microsoft.Extensions.DependencyInjection;
using Microsoft.Extensions.Logging;
using Modbuska.ModbusManager.Extension;
using Serilog;
using Serilog.Events;

Log.Logger = new LoggerConfiguration()
    .MinimumLevel.Information()
    .MinimumLevel.Override("Modbuska", LogEventLevel.Verbose) // Serilog Verbose == Microsoft.Extensions.Logging Trace
    .WriteTo.Console()
    .CreateLogger();

var services = new ServiceCollection();
services.AddLogging(builder => builder.AddSerilog(dispose: true));
services.AddModbus();

Warning: Trace logs every frame on the wire, which includes device data such as slave addresses, function codes, register values and CRC bytes. It also produces a high volume of records. Do not leave Trace enabled on production systems with frequent traffic; keep the level at Warning or higher.

Building and testing

dotnet build
dotnet test

Unit tests use a fake serial connection, so no hardware is needed.

Limitations and roadmap

Current limitations:

  • synchronous (blocking) API only
  • RTU master only
  • no RS-485 direction control options yet (works with USB-RS485 adapters that handle it automatically)

Planned:

  • simpler request API without a custom ModbusMessage subclass
  • typed error codes in results
  • RS-485 settings (RtsEnable, Handshake)
  • async API with CancellationToken

Alternatives

If you need Modbus TCP, async, or a long-established library, look at NModbus or FluentModbus. Modbuska aims to stay small and simple for RTU testing and prototyping.

License

This project is licensed under the MIT License. See the LICENSE file for details.